Fluke 114 Dijital Multimetre

Fluke 114 Dijital Multimetre
Description

Genel Özellikler

Designed for easy one-hand operation, the Fluke 114 true-rms digital multimeter is the perfect troubleshooting tool for “go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. The LoZ function helps identify so-called “ghost voltage and prevent false readings.

The Fluke 114 displays true-rms voltage and current readings with 6000 count resolution, and tests frequency, continuity and resistance. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes easy.

Fluke 114 multimeters are independently tested for safe use in CAT III 600V environments.

And check out other members of the Fluke 110 family: the Fluke 113 Utility Multimeter, the Fluke 115 Field Service Multimeter, the Fluke 116 HVAC Multimeter and the Fluke 117 Commercial Electrician’s Multimeter.

  • AutoVolt: automatic ac/dc voltage selection
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

 

Teknik Özellikler

Specifications
Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
   400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  5 % + 2

Dokümanlar